WTI Inserts conform to all recognised national and international thread and wire thread insert standards.
When installed they provide close tolerance threads which accept both conventional and controlled root radius male threads.
Because of their mechanical advantage, when correctly installed, WTI inserts can easily achieve threaded assemblies where tensile failure of the male thread should occur before insert failure. Clearly a beneficial condition for product design since threaded assemblies can be more accurately calculated around known limits - i.e. bolt yield etc.
|
|
 |
The tables listed below provide a basis for such design, by simply plotting pre-determined values for bolt ultimate tensile against shearing strength of parent material, read the resultant length of insert required to obtain the desired condition.
Shear
Strength of Parent Matl
MPa |
Bolt
/ Male Thread Minimum Ultimate Tensile MPa |
| 390 |
490 |
590 |
790 |
980 |
1180 |
1370 |
| 70 |
2D |
2.5D |
3D |
|
|
|
|
| 100 |
1.5D |
1.5D |
2D |
2.5D |
3D |
|
|
| 150 |
1D |
1.5D |
1.5D |
2D |
2.5D |
3D |
3D |
| 200 |
1D |
1D |
1D |
1.5D |
2D |
2D |
2.5D |
| 250 |
1D |
1D |
1D |
1.5D |
1.5D |
2D |
2D |
| 300 |
1D |
1D |
1D |
1D |
1.5D |
1.5D |
2D |
| 350 |
1D |
1D |
1D |
1D |
1D |
1.5D |
1.5D |
Shear
Strength of Parent Matl
16sF/ft² |
Bolt
/ Male Thread Minimum Ultimate Tensile Tons F/In² |
| 24 |
34 |
43 |
48 |
56 |
59 |
71 |
80 |
98 |
| 70 |
2D |
2½D |
3D |
3D |
|
|
|
|
|
| 100 |
1½D |
1½D |
2D |
2½D |
2½D |
3D |
3D |
|
|
| 140 |
1D |
1½D |
1½D |
2D |
2D |
2D |
2½D |
3D |
|
| 170 |
1D |
1D |
1½D |
1½D |
1½D |
2D |
2D |
2½D |
2½D |
| 210 |
1D |
1D |
1D |
1½D |
1½D |
1½D |
2D |
2D |
2½D |
| 280 |
1D |
1D |
1D |
1D |
1D |
1½D |
1½D |
1½D |
2D |
| 350 |
1D |
1D |
1D |
1D |
1D |
1D |
1D |
1½D |
1½D |
Note: For intermediate values use the next higher column for bolt tensile and the next lower column for parent material strength.
The above figures assume male thread or bolt is fully engaged along the entire length of insert. The above charts are for general guidance only - for specific applications, WTI Engineering can provide more accurate advice and support.

Our BSI registration Certificate is available to download by clicking on the image above. The download size is 1MB.